Product Overview
Product Technical Parameters
Work Environment
Parameter | Min | Type | Max | Unit | Remarks |
Working temperature range | -40 | 25 | 75 | ℃ | up to 55 ℃ will be derated for use |
working humidity range | 45 | 80 | RH % | When the external surface temperature is lower than the dew point, condensation can still operate normally | |
Altitude | 2000 | M | |||
Atmospheric pressure | 70 | 106 | KPa | ||
Cooling method | independent air duct air cooling |
Storage environment
Parameter | Min | Type | Max | Unit | Remarks |
Storage temperature range | -40 | 25 | 90 | ℃ | |
Storage humidity range | 5 | 25 | 95 | RH % | without condensation |
Altitude | 2000 | M | Over 3000 meters, for every 100 meters increase in altitude, the temperature decreases by 1 ℃ | ||
Atmospheric pressure | 70 | 106 | KPa |
Input characteristics
Parameter | Min | Type | Max | Unit | Remarks |
Input voltage range | 260 | 380 | 530 | Vac | |
Input operating frequency | 45 | 50 | 65 | Hz | |
Input power factor | 0.95 | 0.99 | Rated 380 Vac input, rated load output | ||
Total current harmonic value | 5% | Rated power output | |||
Maximum input current | 58 | A | 380Vac | ||
Standby power consumption | <60 | W | without main output and auxiliary power output | ||
Input under voltage | 260 | Vac | undervoltage recovery return difference greater than 10V | ||
Input overvoltage | 530 | Vac | overvoltage recovery return difference greater than 10V | ||
Over temperature protection | 80 | 85 | 90 | ℃ | Shutdown, automatic recovery, intelligent derating of heat sinks above 70 ℃ |
Output Characteristic
Parameter | Type | Unit | Remarks |
Maximum Output Power | 30000 | W | |
Output Voltage Range | 150~1000 | Vdc | |
Output Current Range | 0~100 | A | |
Stable Voltage Accuracy | ±0.5% | % | |
Stable Current Accuracy | ±1 | % | Output load 20% Rated current~maximum current |
Ripple and Noise | ±2 | % | Peak to peak ≤ 2% Vout |
Efficiency | 95 | % | Rated input and output |
Slow Start Time | 3~8 | S | |
Dynamic Response | 50 | mS | 25%~100%~25% load change, output overshoot amplitude ≤ ± 5% |
Output short-circuit protection | Available | ||
Temperature coefficient | ±0.01 | %/℃ | |
Output overvoltage protection | 1025±5 | Vdc | |
Output undervoltage protection | 150±5 | Vdc | |
The battery recharge function | Available | ||
Communication fault protection | Available |
Safety indicators
Parameter | Min | Type | Max | Unit | 备Remarks |
Insulation resistance | 10 | MΩ | 500VDC/10s | ||
Dielectric strength | 0.5 | 12 | mA | 2.0KVac@1min | |
Leakage current | 3.5 | mA | 265Vac/60HZ input | ||
Grounding resistance | 0.1 | Ω | 40A@2min |
EMC Features
Project | Requirements | Standards |
Conducted Emissions (CE) | Class A | Meet NB/T 33008.1-2018 |
Radiation Emission(RE) | Class A | Meet NB/T 33008.1-2018 |
Harmonic current | ≤ 5% @ Output power above half load | Meet GB 17625.6-2008 |
Surge | Severity level 3 | Meet NB/T 33008.1-2018 |
EFT | input and output: 4kV;Signal: 1kV | Refer to EN 61000-4-6 |
ESD | 8kV/15kV | Refer to EN 61000-4-2 |
Conducted immunity | 3Vrms,0.15 ~ 80MHz | Refer to NB/T 33008.1-2018 |
Radiation immunity | 10V/M,80 ~ 2GHz | Meet NB/T 33008.1-2018 |
Mechanical parameters
Project | Parameter | Units |
Size | 530*270*850(width * depth * height) | mm (including gun cable) |
Weight | 60 | kg( including input and output cables) |
Charging gun wire length | 5 | m |